When booting into Exact , software reports a possible database error on **** and requires rebuild.
- close all exact instances on the network
- log into server of exact
- locate exact location eg. D:\databases\exact
- backup all files and folders
- open "exact server administrator"
- icon should now be located in status bar if program is not shown
- right click on icon, click on administer databases
- in left window likely two databases are shown "demo" and "practice"
- right click practice and click on "repair tables"
- unselect all and find the database table previously mentioned and tick, then repair
- test all is ok